From: Fatigue life prediction of pipeline with equivalent initial flaw size using Bayesian inference method
No of Samples
STD
Mean
True
Estimate
5
836
321
8240
7080
15
898
202
8455
7732
30
1039
147
8626
7986
50
1000
116
8580
8165