From: Fatigue life prediction of pipeline with equivalent initial flaw size using Bayesian inference method
No Samples
STD
Mean
True
Estimate
5
482,924
460,000
1,318,528
1,290,000
15
425,447
450,000
1,516,247
1,520,000
30
428,778
420,000
1,493,829
1,460,000
50
412,633
1,578,909
1,570,000